Product Description:
The Honeywell FC-SAO-0220M is a high-integrity Safe Analog Output Module designed for use with Honeywell’s Safety Manager and Safety Manager SC systems (formerly Fail-Safe Control / FSC). As part of a Safety Instrumented System (SIS), it is certified for use in safety loops up to SIL 3 according to IEC 61508, providing precise and reliable control for applications that require modulating output signals.
This module offers 2 independent analog output channels with a 4–20 mA signal, making it ideal for controlling final control elements such as modulating control valves or variable speed drives in safety-critical environments. The FC-SAO-0220M includes extensive internal diagnostics to ensure output integrity and to drive the output to a pre-defined Safe State in case of discrepancies.
SIL 3 Certification: Fully certified for use in SIL 3 safety loops, ensuring compliance with industry safety standards.
Precise Output Control: Provides 4–20 mA analog output with a 12-bit resolution and ±0.1% accuracy, ensuring accurate control of safety-critical systems.
Safe State Protection: Configurable fail-safe behavior for output channels, including 0 mA, < 3.6 mA, or Hold Last Value to prevent unsafe operations.
High Availability: Supports redundant configurations (1oo2), allowing continuous operation even if one module fails.
Hot-Swappable: Designed for online replacement, enabling maintenance without disrupting the safety system.
HART Compatibility: Often supports HART pass-through, allowing communication with smart field instruments for enhanced diagnostics and maintenance.
Corrosion Protection: Features a G3 conformal coating, ensuring durability in harsh industrial environments like oil rigs and chemical refineries.
| Feature | Specification |
|---|---|
| Number of Channels | 2 Isolated Channels |
| Signal Range | 4-20 mA (0-22 mA for over-range/under-range) |
| Resolution | 12-bit (minimum) |
| Load Impedance | Up to 600Ω at 24V DC |
| Accuracy | ±0.1% of full scale |
| Safety Integrity Level (SIL) | SIL 3 (IEC 61508) |
| Read-back Monitoring | Continuous loop monitoring for fault detection |
| Safe State | Configurable (e.g., 0 mA, < 3.6 mA, Hold Last Value) |
| Line Monitoring | Detects open circuits and short circuits |
| Power Supply | 24 V DC (module dependent) |
| Isolation | Galvanic isolation between field-side and internal bus |
| Status Indicators | RUN (Green), FAIL (Red), CH1/CH2 (Channel Status LEDs) |
| Operating Temperature | -5°C to +70°C |
| Humidity | 5% to 95% RH (non-condensing) |
| Dimensions | Standard 1U width |
The FC-SAO-0220M is ideal for use in industries where precise analog output control is essential for safety-critical operations, including:
Oil & Gas
Chemical Processing
Petrochemical
Power Generation
Refining
Q: What is the maximum load impedance supported by the FC-SAO-0220M?
A: The module can support loads up to 600Ω at 24V DC.
Q: How does the module ensure safety in case of discrepancies in the output signal?
A: The module continuously monitors the output current and can drive the output to a pre-defined Safe State if the read-back value deviates beyond the acceptable tolerance.
Q: Can the module be replaced without shutting down the system?
A: Yes, the FC-SAO-0220M is hot-swappable, allowing safe replacement while the system remains operational.